Theme
PHASE 6 RC • Phase 5 theme layer completeEarth Commercial • STS / STB / STW / STD / STK
Ultrasonic Hygiene Suite › Sonic Kitchen / Dishwasher
STK • 25–50 kHz current UST baseline; 28/40 kHz candidates under studyNo human or animal occupancy during operationService / calibration / future quantum-sensor modes: empty-only
Sonic Kitchen / Dishwasher
STK • Dish / Utensil Cleaning

Sonic Kitchen / Dishwasher

A rigid-load cleaning platform using controlled liquid-coupled acoustics, filtration, load-specific modes and forced-air finishing for dishes, utensils and compatible cookware.

Concept Development3D CAD ReadyShared UST CoreSafety-Bounded
STK Model Gallery

Different configurations for different markets

These renderings are design studies rather than frozen production SKUs. Final dimensions, controls, finishes and component packaging will be established in 3D CAD and prototype testing.

Current Concept Specifications

Design-study envelope

Acoustic Study Range25–50 kHz current UST baseline; 28/40 kHz candidates under research
Coupling MediumLiquid / semi-immersed / controlled rinse coupling
Occupancy RuleNever operate with a person or animal inside
Water / Fluid InterfaceReservoir or building feed depending model; filtration loop
ElectricalCommon UST electrical architecture; final generator TBD

Frequency values shown here are current UST concept-study ranges from the program architecture, not released product specifications or human exposure limits.

Operating Experience

Selectable modes

Glassware

Gentler acoustic profile for compatible delicate loads.

Normal

Balanced everyday dish cycle.

Heavy

More aggressive soil-removal mode for compatible cookware.

Quick

Short refresh/light-soil cycle.

Rinse / Filter

Fluid circulation and debris removal.

Dry

Forced-air finishing after drain.

Control Interface

Ten control / status functions to define

The final interface may use physical buttons, sealed switches, touch controls, indicators or a combination. The website shows functions, not a frozen hardware layout.

Power / standbyFinal label, icon, hardware and control behavior remain subject to HMI engineering.
Load / mode selectionFinal label, icon, hardware and control behavior remain subject to HMI engineering.
Cycle intensityFinal label, icon, hardware and control behavior remain subject to HMI engineering.
Estimated timeFinal label, icon, hardware and control behavior remain subject to HMI engineering.
Acoustic zone statusFinal label, icon, hardware and control behavior remain subject to HMI engineering.
Water / reservoir statusFinal label, icon, hardware and control behavior remain subject to HMI engineering.
Filter / drain statusFinal label, icon, hardware and control behavior remain subject to HMI engineering.
Door / occupancy interlockFinal label, icon, hardware and control behavior remain subject to HMI engineering.
Pause / emergency stopFinal label, icon, hardware and control behavior remain subject to HMI engineering.
Complete / service / fault indicationFinal label, icon, hardware and control behavior remain subject to HMI engineering.
Public-Safe Architecture

How the system works without exposing proprietary geometry

Open How-It-Works
Load

Secure compatible items with field-aware rack geometry.

Fill

Establish validated fluid level and coupling condition.

Clean

Apply selected acoustic profile and sweep strategy.

Filter

Move contamination through controlled filtration / drain path.

Dry

Drain and use forced airflow to reduce retained moisture.

Safety Architecture

Interlocks, warnings and safe-state behavior

Occupancy prohibition

No humans or animals; occupancy detection inhibits high-energy operation.

Fluid-level interlock

High-power liquid-coupled modes cannot run dry.

Door interlock

Opening the door disables acoustic drive and active fluid motion.

Foreign-object / load check

Unexpected loose objects or incompatible conditions trigger pause/alert.

Generator protection

Impedance shift, overcurrent or resonance fault causes fast derating.

Temperature monitoring

Tank, fluid, transducers and power electronics remain bounded.

Leak / overflow protection

Independent water-level and leak sensors inhibit fill/drive as needed.

Filter / drain monitoring

Blocked waste path prevents continuation into unsafe conditions.

Service calibration empty-only